Energis Academy

Energy management glossary

The terms energy professionals use every day, each defined in one or two sentences, with an example and where Energis.Cloud does it.

B

Building automation and control system (BACS)
A building automation and control system (BACS) is the set of products, software and services that monitor, log, analyse and adjust a building's technical systems, such as heating, cooling, ventilation and lighting. EU law requires one in larger non-residential buildings.

D

Degree days
Degree days measure how much heating or cooling the weather called for over a period. Heating degree days add up, day by day, how far the mean outdoor temperature fell below a base temperature; cooling degree days add up how far it rose above one.

E

Energy baseline
An energy baseline is the reference consumption of a building, site or installation over a chosen period, used to measure later savings against. It is usually adjusted for what drives consumption, such as the weather, production or occupancy.
Energy performance certificate (EPC)
An energy performance certificate (EPC) rates a building's energy performance on a scale, often from A to G, with recommendations to improve it. It is required when a building is built, sold or rented. In Belgium it is called EPC in Flanders and PEB in Brussels and Wallonia.
Energy performance indicator (EnPI)
An energy performance indicator (EnPI) is a value an organisation chooses to measure its energy performance, such as kWh per m², kWh per tonne produced or kWh per guest night. ISO 50001 asks organisations to set EnPIs and follow them against an energy baseline.

I

International Performance Measurement and Verification Protocol (IPMVP)
The International Performance Measurement and Verification Protocol (IPMVP) is the most widely used framework for measuring and verifying energy savings. Published by the Efficiency Valuation Organization, it sets how to define a baseline, adjust it and report the savings, with four options, A to D.

O

Out-of-hours consumption
Out-of-hours consumption is the energy a building uses outside its opening hours: at night, at weekends and on public holidays. Part of it is needed, such as servers, refrigeration and frost protection; the rest is usually waste, and often the quickest saving to find.

P

Power peak
A power peak is the highest power a site draws from the grid over a metering interval, often 15 minutes, in a month or a year. Grid tariffs and supply contracts often charge for it, and drawing more than the contracted power can bring penalties.

S

Self-consumption
Self-consumption is the part of the electricity produced on site, by solar panels or a cogeneration unit, that the building uses itself instead of sending it to the grid. Every kWh used on site is a kWh not bought.
Sub-metering
Sub-metering means installing meters downstream of the main meter, so that a floor, a tenant, a production line or a single installation is measured on its own. It shows where energy goes, which the main meter alone cannot.

See these ideas at work in a demo

Energis.Cloud keeps the measured data behind each of these terms. Request a demo and we show it on a set-up close to yours.

The metrics of a demo site in Energis.Cloud: each one with its type, unit, formula and the data it depends on, such as cooling degree days from the outdoor temperature